About the product
Central Loose Tube Cable for Indoor Use
Description
The fibers,250μm, either of single-mode or multimode type, are positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. A layer of aramid yarn or high strength glass is applied around the cable core as additional strength member. Then, the cable is completed with a black or color HDPE sheath.
Application
-Adopted to indoor and outdoor distribution.
-Suitable for communication equipment serve.
Characteristics
Non-mental design can prevent the cable from radio interference and magnetic wave interference
Specially designed compact structure is good at preventing loose tubes from shrinking
Aramid yarn ensures good performance of tensile strength
Loose tube filling compound ensure good moisture resistance performance
Good flexibility
High dense fiber packed, small diameter and light weight; it's the better option for blowing installation process
Application
Adopted to backbone network, access network and fiber to the home.
Adopted to backbone network, access network and fiber to the home.
Optical Characteristics
G.652 G.655 50/125μm OM2 62.5/125μm
Attenuation @850nm ≤3.0 dB/km ≤3.0 dB/km
(+20℃) @1300nm ≤1.0 dB/km ≤1.0 dB/km
@1310nm ≤0.36 dB/km ≤0.40 dB/km
@1550nm ≤0.22 dB/km ≤0.23dB/km
Bandwidth (Class A) @850nm ≥500 MHz·km ≥200 MHz·km
@1300nm ≥1000 MHz·km ≥600 MHz·km
Numerical Aperture 0.200±0.015NA 0.275±0.015NA
Cable Cut-off Wavelength λcc ≤1260nm ≤1480nm
Technical Parameters
Cable Type Fiber Count Cable Diameter mm Cable Weight kg/km Tensile Strength Crush Resistance Bending Radius
Long/Short Term N Long/Short Term N/100mm Static /Dynamic mm
Jet 2~24 6 30 150/300 200/500 15D/30D
Central Loose Om3 Pulling Fiber Optic Cable Through Ducts 250um 12F 6MM HDPE 0
Description
The fibers,250μm, either of single-mode or multimode type, are positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. A layer of aramid yarn or high strength glass is applied around the cable core as additional strength member. Then, the cable is completed with a black or color HDPE sheath.
Application
-Adopted to indoor and outdoor distribution.
-Suitable for communication equipment serve.
Characteristics
Non-mental design can prevent the cable from radio interference and magnetic wave interference
Specially designed compact structure is good at preventing loose tubes from shrinking
Aramid yarn ensures good performance of tensile strength
Loose tube filling compound ensure good moisture resistance performance
Good flexibility
High dense fiber packed, small diameter and light weight; it's the better option for blowing installation process
Application
Adopted to backbone network, access network and fiber to the home.
Adopted to backbone network, access network and fiber to the home.
Optical Characteristics
G.652 G.655 50/125μm OM2 62.5/125μm
Attenuation @850nm ≤3.0 dB/km ≤3.0 dB/km
(+20℃) @1300nm ≤1.0 dB/km ≤1.0 dB/km
@1310nm ≤0.36 dB/km ≤0.40 dB/km
@1550nm ≤0.22 dB/km ≤0.23dB/km
Bandwidth (Class A) @850nm ≥500 MHz·km ≥200 MHz·km
@1300nm ≥1000 MHz·km ≥600 MHz·km
Numerical Aperture 0.200±0.015NA 0.275±0.015NA
Cable Cut-off Wavelength λcc ≤1260nm ≤1480nm
Technical Parameters
Cable Type Fiber Count Cable Diameter mm Cable Weight kg/km Tensile Strength Crush Resistance Bending Radius
Long/Short Term N Long/Short Term N/100mm Static /Dynamic mm
Jet 2~24 6 30 150/300 200/500 15D/30D
Central Loose Om3 Pulling Fiber Optic Cable Through Ducts 250um 12F 6MM HDPE 0
Contact with supplier